Transformer - serie G grounded center

 

The outputs can be constructed according to the application. The best insulation is ensured in extremely difficult and special conditions. This is produced, like the whole range, with input voltages between 100 and 400V, in accordance with international standards and with customers' requirements. The main intermittent and continuous models are technically approved - in accordance with VDE and SEV regulations - and can include accessories for Electromagnetic Compatibility, as tested in our laboratory.

 
 
Type

Supply Voltage V(50 Hz)

Primary CurrentA(50 Hz)

Power
VA

Secondary Voltage kV
Seconary Current mA
Secondary Peak Voltage kV
Duty ED% min.
               
TRG1015C
220-230
0,85
187
2x5
15
14
DB Continuo
TRG1015C
380/400
0,5
200
2x5
15
14
DB Continuo
TRG1020C
220-230
1
230
2x5
20
14
DB Continuo
TRG1020C
380/400
0,6
240
2x5
20
14
DB Continuo
TRG1035
220-230
2,1
483
2x5
35
14
AB 25% 4min 4 min.
TRG1035 US
120 60Hz
3,4
408
2x5
35
14
AB 25% 4min 4 min.
TRG1225
200 50-60Hz
1,4
280
2x6
25
17
AB 25% 4min 4 min.
TRG1230
220-230
2,2
506
2x6
30
17
AB 25% 4min 4 min.

C=
V=
S=
UL=


L= Turn on a neon-lamp of 11-15 W (primary)

Standard Value Table. On customer's specifications, we can provide for special primary voltages, either 50Hz or 60 Hz.

 
 