iGas

Automatic control for gas burners with ignition and flame detection integrated

It allows the control of a single direct ignition burner till 350kW, with flame detection integrated (single electrode) or separate electrode.
i-GAS  can freely fit to many different application conditions thanks to its easy programmability.
Some parameters are factory settled and password protected, directive compliant, others are customizable following customer’s needs.

Advanced self diagnostic system

An advanced self diagnostic system provide through an alphanumeric display all information about the cycle, lock causes, eventual applied
device’s failures, or burner’s failures.
The reset push button, and its warning light, can be remoted through a socket connection.

Easy serviceability

The ignition transformer provide a high energy spark that warrant the ignition in every situation.
It is possible to use the same ignition electrode both to make ignition and flame readings. For ionization, or with a separate electrode
(dedicated), plugging it directly to the control device socket.  The socket give to the device easy serviceability, allowing quick plug/unplug
operability.

Total Control

i-GAS  represents the burner’s supervisor being active all the time the power is on, even when the thermo switch do not require heat.

All connected devices are monitored all the time, even in stand by condition.

Any uneven failure might be detected before power heat is demanded by the thermo switch.

The circuit configuration allows the manufacturer to simplify cable harness of burners main case.

Specifiche tecniche
Power Supply230V +/-15%
Frequency *50/60Hz
Power Consumtion3 VA Max
Power Dissipation2W Max
Max output’s current3 A @ 230 V cosf 0,4
Line Fuse5×20 mm RAPIDO 3,15A
Working temperature range0 / 60°C
Storage temperature range-20 / 80°C
Relative umidity45 / 85 %
Enclosure Nylon UL94 V-0115x97x41 mm
IP degree EN60529IP00
Weight400g Max
Pre-blowing1 / 250 s
Pre-ignition500 ms


Safety time on ignition2 / 25 s
Safety time running1 / 12 s
Post-blowing1 / 250 s
Allowed Post-combustion time< 20 s[/av_cell][/av_row] [av_row row_style='' av_uid='av-8juplb'][av_cell col_style='avia-desc-col' av_uid='av-8aic0v']Auto shutoff & timer (optional)[/av_cell][av_cell col_style='' av_uid='av-84sqsf']00h05m / 20h50m[/av_cell][/av_row] [av_row row_style='' av_uid='av-803s87'][av_cell col_style='avia-desc-col' av_uid='av-7v6cvr']Ignition Cycle counter [/av_cell][av_cell col_style='' av_uid='av-7mxbzb']524288[/av_cell][/av_row] [av_row row_style='' av_uid='av-7ks2cf'][av_cell col_style='avia-desc-col' av_uid='av-7b7fpj']Minimum ionization current[/av_cell][av_cell col_style='' av_uid='av-76p0hj']> 1mA
Ionization current limits0,5 mA
Flame detection probe voltage250 V ac
Flame detection probe insulation> 50 MOmega
Flame detection probe wire lenght< 30 m[/av_cell][/av_row] [av_row row_style='' av_uid='av-529j8v'][av_cell col_style='avia-desc-col' av_uid='av-4tgapz']Single electrode wire lenght[/av_cell][av_cell col_style='' av_uid='av-4o22fr']< 1 m[/av_cell][/av_row] [av_row row_style='' av_uid='av-4mntsn'][av_cell col_style='avia-desc-col' av_uid='av-4goj0v']Output ignition Voltage[/av_cell][av_cell col_style='' av_uid='av-468btb']1 x 15 kV +/- 10%[/av_cell][/av_row] [av_row row_style='' av_uid='av-eo6mn'][av_cell col_style='avia-desc-col' av_uid='av-3xxb5j']Short circuit ignition current[/av_cell][av_cell col_style='' av_uid='av-3nvmbj']30 mA rms +/- 10%[/av_cell][/av_row] [/av_table] [/av_one_half] [av_three_fourth first av_uid='av-3i2zin'] [av_textblock av_uid='av-3dono7'] Conformità
[/av_textblock]


Direttiva per apparecchi a gas ((2009/142/CE)
Conform to EN230
Direttiva per bassa tensione (2006/95/CE)Conform to EN746-2
Direttiva Macchine (2006/42/CE)Conform to UNI10156
Direttiva EMC (2004/108/CE)DPR 15 november 1996 n°661
Conform to EN298

[/av_three_fourth]

Applicazioni